• CP1500T100
  • CP1500T100

CP1500T100

High-voltage CP1500 Series 1500W AC/DC battery charger with 100V battery charging platform, up to 10A charging current, built-in LFP and NCM lithium-ion charging curves, and a compact 127.3 × 215.6 × 43mm design. Built with 90–264VAC no-derating universal input, battery reverse connection protection, remote control functions, CAN communication, and 2xMOPP isolation, it is ideal for industrial equipment, medical battery systems, AGV charging applications, and high-voltage linear motor solutions.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Rated Voltage
100V
Charge Current
15A
Rated Power
1500W
Outline
8.5"x5"x1.69" or 215.6mmx127.2mmx43mm
EMC
Class B Emission
Peak Efficiency @230Vac
94%
  • CP1500T100

Description

30-Second Fit Check

  • Choose CP1500T100 when your charger must tolerate wide AC mains (90–264Vac) while delivering 1500W to a 100V-class pack.
  • Charge profiles are built-in for LiFePO4 (LFP) and NCM chemistries—verify your series count and required full-charge voltage.
  • Need up to 10A? This model’s max charge current supports higher throughput charging (within your pack’s limits).
  • If your controller needs charger status/control, the series supports CAN plus remote-control features (per datasheet).
  • Mechanical check: compact form factor is specified as 5.0" × 8.5" × 1.58" (127.3 × 215.6 × 43 mm).
  • Compliance planning: confirm the charger’s stated safety/EMC items align with your end-product requirements.

What it is & why it matters

  • Single-phase universal input simplifies site installs—no voltage-select switches to manage.
  • Reverse-polarity connection detection helps reduce wiring mistakes during service.
  • Remote ON/OFF control supports system-level interlocks and sequencing.
  • Compact mechanical envelope makes it easier to embed into AGV docks and cabinet builds.

Key Specs

  • Output power: 1500W
  • Max charge current: 10A
  • AC input: Single-phase 90–264Vac (rated 100–240Vac)
  • Input frequency: 47–63Hz (rated 50–60Hz)
  • Aux output: 12V, 1A max
  • Output regulation: <3% (includes line & load regulation)
  • Output current ripple: 10% peak-to-peak
  • Efficiency: Up to 94% max (48V models, excluding fan power)
  • Operating altitude: 5000 m operating altitude
  • Dimensions: 5.0" × 8.5" × 1.58" (127.3 × 215.6 × 43 mm)
  • LFP profile: 32S LiFePO4: FC 115.2V (Vnor 102.4V)
  • NCM profile: 27S NCM: FC 113.4V (Vnor 97.2V)

Integration & Controls

  • Controls & comms: Remote voltage sense compensation, remote ON/OFF control, CAN communication
  • Remote sense: supports remote voltage detection compensation (per datasheet)
  • Remote control: remote ON/OFF function specified (per datasheet)
  • Thermal management: smart fan speed control specified

Best for / Not for

Best for

  • 100V-class packs that match one of the built-in profiles (e.g., 32S LiFePO4; 27S NCM).
  • AGV and automation teams that want predictable integration options (CAN + remote control features).
  • Programs that want a compact charger footprint with a specified auxiliary 12V/1A output.

Not for

  • Battery programs that require a fully user-programmable charge algorithm beyond the built-in curves.
  • Packs needing systems that require adjustable high-voltage profiles not covered by the built-in LFP/NCM curves.
  • Installations needing three-phase AC input (not specified for this series).

Typical Applications

  • medical equipment
  • industrial equipment
  • robot vacuum charging modules
  • AGV charging modules
  • linear motor systems

Selection Checklist

  • Profile selection: pick the correct built-in LFP or NCM curve and verify the FC voltage matches your pack.
  • Wiring: decide if remote sense is needed to compensate for harness voltage drop.
  • Comms: if using CAN, confirm message/command mapping during commissioning.
  • Aux power: plan use of the 12V/1A auxiliary output (or leave unused).
  • Compliance planning: align the stated safety/EMC items with your product requirements.

Compliance, Isolation & Reliability

  • Isolation: Medical-grade 2×MOPP isolation; dielectric ratings 4000Vac (primary-to-secondary); 1500Vac (primary-to-earth); 1500Vac (secondary-to-earth)
  • Leakage current: Contact leakage current <100µA; earth leakage current <300µA
  • Safety: IEC/UL 62368-1 + CAN/CSA 62368-1; EN/UL 60335-1
  • EMC: EMC Class B conducted & radiated emissions; meets IEC 60601-1-2 (4th edition)
  • Reliability: MTBF > 500k hours
RFQ Quick Checklist
  • Model: CP1500T100 (or tell us your battery series count + full-charge voltage)
  • Quantity & target delivery date
  • Battery chemistry (LFP or NCM) + series count
  • Required full-charge voltage (FC) + target charge current
  • Need CAN communication? (Y/N) Need remote ON/OFF or remote sense? (Y/N)
  • Install constraints (enclosure space, airflow, altitude)
Note: Final compliance and in-system performance depend on your end-product design, wiring, enclosure, thermal management, and verification testing.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.