• CP1500T24
  • CP1500T24

CP1500T24

High-current CP1500 Series 1500W AC/DC battery charger with 24V battery charging platform, up to 62.5A charging current, built-in LFP and NCM lithium-ion charging curves, and a compact 127.3 × 215.6 × 43mm enclosure. Featuring 90–264VAC no-derating universal input, 2xMOPP isolation, CAN communication, and remote control functions, it is ideal for industrial equipment, medical battery systems, AGV charging modules, linear motors, and collaborative robots.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Rated Voltage
24V
Charge Current
62.5A
Rated Power
1500W
Outline
8.5"x5"x1.69" or 215.6mmx127.2mmx43mm
EMC
Class B Emission
Peak Efficiency @230Vac
93.50%
  • CP1500T24

Description

30-Second Fit Check

  • Match if you need a 1500W charger for a 24V-class lithium pack and your site power is Single-phase 90–264Vac (rated 100–240Vac).
  • Charge profiles are built-in for LiFePO4 (LFP) and NCM chemistries—verify your series count and required full-charge voltage.
  • Electrical fit check: model max current is 62.5A; size your fuse, wiring, and thermal design accordingly.
  • If your controller needs charger status/control, the series supports CAN plus remote-control features (per datasheet).
  • Space planning: the charger footprint is 5.0" × 8.5" × 1.58" (127.3 × 215.6 × 43 mm)—confirm enclosure fit and airflow path.
  • Compliance planning: confirm the charger’s stated safety/EMC items align with your end-product requirements.

What it is & why it matters

  • Built-in LFP/NCM curves reduce engineering effort when you’re validating battery profiles.
  • CAN communication provides a path for supervisory control and diagnostics.
  • Automatic full-charge stop supports hands-off charging behavior in fleet operations.
  • Smart fan speed control helps balance cooling needs and noise/power draw (per datasheet).

Key Specs

  • Output power: 1500W
  • Max charge current: 62.5A
  • AC input: Single-phase 90–264Vac (rated 100–240Vac)
  • Input frequency: 47–63Hz (rated 50–60Hz)
  • Aux output: 12V, 1A max
  • Output regulation: <3% (includes line & load regulation)
  • Output current ripple: 10% peak-to-peak
  • Efficiency: Up to 94% max (48V models, excluding fan power)
  • Operating altitude: 5000 m operating altitude
  • Dimensions: 5.0" × 8.5" × 1.58" (127.3 × 215.6 × 43 mm)
  • LFP profile: 7S LiFePO4: FC 25.2V (Vnor 22.4V)
  • NCM profile: 6S NCM: FC 25.2V (Vnor 21.6V)

Integration & Controls

  • CAN communication: supported (per datasheet) for monitoring/control integration.
  • Battery handling: automatic battery connection detection and reverse-polarity detection are specified.
  • Charge completion: automatic full-charge stop is specified.
  • Cooling: smart fan speed control is specified.

Best for / Not for

Best for

  • 24V-class packs that match one of the built-in profiles (e.g., 7S LiFePO4; 6S NCM).
  • AGV and automation teams that want predictable integration options (CAN + remote control features).
  • Programs that want a compact charger footprint with a specified auxiliary 12V/1A output.

Not for

  • Battery programs that require a fully user-programmable charge algorithm beyond the built-in curves.
  • Packs needing profiles requiring ~28.8V/29.4V full-charge (28V-class strings).
  • Installations needing three-phase AC input (not specified for this series).

Typical Applications

  • industrial equipment
  • linear motor systems
  • medical equipment
  • robot vacuum charging modules
  • AGV charging modules

Selection Checklist

  • Profile selection: pick the correct built-in LFP or NCM curve and verify the FC voltage matches your pack.
  • Wiring: decide if remote sense is needed to compensate for harness voltage drop.
  • Comms: if using CAN, confirm message/command mapping during commissioning.
  • Aux power: plan use of the 12V/1A auxiliary output (or leave unused).
  • Compliance planning: align the stated safety/EMC items with your product requirements.

Compliance, Isolation & Reliability

  • Isolation: Medical-grade 2×MOPP isolation; dielectric ratings 4000Vac (primary-to-secondary); 1500Vac (primary-to-earth); 1500Vac (secondary-to-earth)
  • Leakage current: Contact leakage current <100µA; earth leakage current <300µA
  • Safety: IEC/UL 62368-1 + CAN/CSA 62368-1; EN/UL 60335-1
  • EMC: EMC Class B conducted & radiated emissions; meets IEC 60601-1-2 (4th edition)
  • Reliability: MTBF > 500k hours
RFQ Quick Checklist
  • Model: CP1500T24 (or tell us your battery series count + full-charge voltage)
  • Quantity & target delivery date
  • Battery chemistry (LFP or NCM) + series count
  • Required full-charge voltage (FC) + target charge current
  • Need CAN communication? (Y/N) Need remote ON/OFF or remote sense? (Y/N)
  • Install constraints (enclosure space, airflow, altitude)
Note: Final compliance and in-system performance depend on your end-product design, wiring, enclosure, thermal management, and verification testing.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.