• CP1500T48
  • CP1500T48

CP1500T48

High-efficiency CP1500 Series 1500W AC/DC battery charger with 48V battery charging platform, up to 31.2A charging current, built-in LFP and NCM lithium-ion charging curves, and up to 94% efficiency in a compact 127.3 × 215.6 × 43mm enclosure. Featuring 90–264VAC no-derating universal input, 2xMOPP isolation, intelligent fan speed control, and remote control functions, it is ideal for industrial equipment, medical systems, AGV charging modules, cleaning robot chargers, and linear motor applications.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Rated Voltage
48V
Charge Current
31.2A
Rated Power
1500W
Outline
8.5"x5"x1.69" or 215.6mmx127.2mmx43mm
EMC
Class B Emission
Peak Efficiency @230Vac
94%
  • CP1500T48

Description

30-Second Fit Check

  • Match if you need a 1500W charger for a 48V-class lithium pack and your site power is Single-phase 90–264Vac (rated 100–240Vac).
  • Best if you want pre-defined LFP/NCM curves (not a blank, user-programmable charger profile).
  • Electrical fit check: model max current is 31.2A; size your fuse, wiring, and thermal design accordingly.
  • Integration options include CAN communication, remote ON/OFF, and remote voltage sense compensation (per datasheet).
  • Packaging constraint: plan around 5.0" × 8.5" × 1.58" (127.3 × 215.6 × 43 mm) and fan-assisted cooling (smart fan control specified).
  • Compliance planning: confirm the charger’s stated safety/EMC items align with your end-product requirements.

What it is & why it matters

  • Wide-range input (90–264Vac) helps you standardize one charger across multiple facilities.
  • Remote voltage sense compensation can reduce end-of-charge error caused by cable drop.
  • Automatic battery connection detection supports cleaner docking/connection workflows.
  • 12V/1A auxiliary output can power local control electronics near the charger.

Key Specs

  • Output power: 1500W
  • Max charge current: 31.2A
  • AC input: Single-phase 90–264Vac (rated 100–240Vac)
  • Input frequency: 47–63Hz (rated 50–60Hz)
  • Aux output: 12V, 1A max
  • Output regulation: <3% (includes line & load regulation)
  • Output current ripple: 10% peak-to-peak
  • Efficiency: Up to 94% max (48V models, excluding fan power)
  • Operating altitude: 5000 m operating altitude
  • Dimensions: 5.0" × 8.5" × 1.58" (127.3 × 215.6 × 43 mm)
  • LFP profile: 15S LiFePO4: FC 54.8V (Vnor 48.0V)
  • LFP profile: 16S LiFePO4: FC 58.4V (Vnor 51.2V)
  • NCM profile: 13S NCM: FC 54.6V (Vnor 46.8V)
  • NCM profile: 14S NCM: FC 58.8V (Vnor 50.4V)

Integration & Controls

  • Controls & comms: Remote voltage sense compensation, remote ON/OFF control, CAN communication
  • Remote sense: supports remote voltage detection compensation (per datasheet)
  • Remote control: remote ON/OFF function specified (per datasheet)
  • Thermal management: smart fan speed control specified

Best for / Not for

Best for

  • 48V-class packs that match one of the built-in profiles (e.g., 15S LiFePO4; 16S LiFePO4; 13S NCM; 14S NCM).
  • AGV and automation teams that want predictable integration options (CAN + remote control features).
  • Programs that want a compact charger footprint with a specified auxiliary 12V/1A output.

Not for

  • Battery programs that require a fully user-programmable charge algorithm beyond the built-in curves.
  • Packs needing profiles that need 72V-class full-charge voltages (mid‑80V range).
  • Installations needing three-phase AC input (not specified for this series).

Typical Applications

  • robot vacuum charging modules
  • medical equipment
  • industrial equipment
  • AGV charging modules
  • linear motor systems

Selection Checklist

  • Battery match: confirm chemistry (LFP/NCM), series count, and the required full-charge voltage (FC).
  • Current planning: validate pack/BMS current limits against the model’s max current.
  • Controls: define whether you’ll use CAN, remote ON/OFF, and remote sense in your architecture.
  • AC infrastructure: confirm 90–264Vac single-phase availability at the dock/cabinet.
  • Mechanical & cooling: fit the specified dimensions and provide airflow for fan-assisted cooling.
  • Altitude & environment: check the 5000 m operating altitude spec vs your deployment conditions.

Compliance, Isolation & Reliability

  • Isolation: Medical-grade 2×MOPP isolation; dielectric ratings 4000Vac (primary-to-secondary); 1500Vac (primary-to-earth); 1500Vac (secondary-to-earth)
  • Leakage current: Contact leakage current <100µA; earth leakage current <300µA
  • Safety: IEC/UL 62368-1 + CAN/CSA 62368-1; EN/UL 60335-1
  • EMC: EMC Class B conducted & radiated emissions; meets IEC 60601-1-2 (4th edition)
  • Reliability: MTBF > 500k hours
RFQ Quick Checklist
  • Model: CP1500T48 (or tell us your battery series count + full-charge voltage)
  • Quantity & target delivery date
  • Battery chemistry (LFP or NCM) + series count
  • Required full-charge voltage (FC) + target charge current
  • Need CAN communication? (Y/N) Need remote ON/OFF or remote sense? (Y/N)
  • Install constraints (enclosure space, airflow, altitude)
Note: Final compliance and in-system performance depend on your end-product design, wiring, enclosure, thermal management, and verification testing.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.