• KFS1200T60
  • KFS1200T60

KFS1200T60

High-density KFS1200 Series 1200W AC/DC power supply with 60VDC output, 20A rated current, and 54–66V adjustable range in a compact 108.8 × 278.1 × 41mm housing. Designed with 90–264VAC universal input, peak power up to 3800W for 5 seconds, active current sharing, and remote voltage sensing, it is well suited for industrial and medical equipment, collaborative robots, and linear motor applications.

Input Voltage Range
Single-phase 90VAC - 264VAC
Input Voltage Frequency
50Hz - 60Hz
Output Voltage
60V
Rated Current
0-20A
Peak Output Current
63A
Rated Power
1200W
Peak Output Power
3800W @ Vin≥220VAC
Output Ripple
≤1%
Peak Efficiency @230Vac
94% (exclude fan power)
Outline
4.28“x10.95”x1.61“ or 108.8mmx278.1mmx41mm
EMC
CLASS B Conducted and CLASS A Radiated Emissions
  • KFS1200T60

Description

30-Second Fit Check

  • Output rail: 60V DC at 20A (1200W)
  • Output trim: adjustable 54–66V for setpoint tuning
  • Peak capability: series peak power spec listed as 3800W/5s (input ≥180VAC)
  • Input: single-phase 90–264VAC (47–63Hz)
  • Controls/comms: DC_OK + remote sense + remote on/off; PMBus/CANBus optional

What It Is & Why It Matters

  • 1200W platform with monitoring hooks so integration teams can build “power health” into the system
  • Remote sense supports tighter voltage control at the load when wiring resistance is non-trivial
  • Optional PMBus/CANBus helps projects that want a path to telemetry/control (confirm ordering options)
  • Active current sharing supports designs that distribute load across units (system design dependent)

Key Specs

  • Rated output: 60V, 20A (1200W)
  • Peak power (series): 3800W for 5s when input ≥180VAC
  • Output quality (series): ripple 1% p‑p; dynamic response <5%; regulation <3%
  • Aux rail (series): 5V / 2A max
  • Mechanical (series): compact dimensions are listed in the datasheet

Integration & Controls

  • DC_OK analog indication signal
  • Remote sampling / remote sense compensation
  • Remote on/off control
  • PMBus or CANBus options
  • Series lists operation up to 5000m altitude

Best for / Not for

  • Best for: 60V rails needing a broad 54–66V trim range and DC_OK monitoring
  • Best for: builds planning for optional PMBus/CANBus integration
  • Not for: applications that must be fanless (fan speed control is listed for the series)
  • Not for: systems requiring input below 90VAC or peak use outside the datasheet input condition

Typical Applications & Selection Checklist

  • Applications (listed/implied): industrial/medical AC/DC systems; collaborative robotics subsystems
  • Setpoint check: confirm target voltage fits 54–66V
  • Monitoring check: decide how you’ll use DC_OK (controller input, alarm, service routine)
  • Comms check: if PMBus/CANBus is required, confirm the correct ordering option
  • Thermal check: validate airflow and cabinet temperature during verification testing
RFQ Quick Checklist
  • Quantity + target delivery date
  • Setpoint within 54–66V + continuous current requirement
  • Peak event profile (duration/frequency) + input voltage condition
  • Need current sharing (Y/N); need PMBus/CANBus (Y/N)
  • Install constraints: airflow, ambient, altitude
Note: Final compliance/performance depend on end-product design and verification testing. Certifications may vary by model—see datasheet.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.