• TBM15-13K5THI(R)F
  • TBM15-13K5THI(R)F
  • TBM15-13K5THI(R)F
  • TBM15-13K5THI(R)F

TBM15-13K5THI(R)F

Compact TBM series three-phase low-voltage AC-DC bidirectional power module with 15VDC output, 900A rated current, 13.5kW power, 380/400/415VAC 3Ph+PE input, and a compact 218 × 86 × 300mm design. Featuring high-frequency isolation, up to 93.5% AC-to-DC efficiency and 92% DC-to-AC efficiency, PF above 0.99, THDi below 5%, CAN communication, intelligent forced-air cooling, and parallel expansion up to 4 units, it is ideal for cell formation and test equipment, bidirectional power testing, and energy-recyclable power aging applications.

Wiring Mode
3Ph+PE
AC Input Rated Voltage
380/400/415VAC
DC Output Rated Voltage
15VDC
DC Output Rated Current
900A
Power Direction
Bidirectional
Expandability
4
Size(W*H*D)
218mm*86mm*300mm
Weight
≤6.5kg
  • TBM15-13K5THI(R)F
  • TBM15-13K5THI(R)F

Description

Model: TBM15-13K5THI(R)F Wiring: 3Ph+PE No neutral line / no neutral current

Key specifications

  • Rated output capacity: 13.5kW (AC→DC)
  • AC input: 380/400/415VAC; 343–456VAC full load; 304–343VAC derating to 80%
  • DC output: 15VDC, 900A
  • DC→AC rated input capacity: 10.8kW; DC input: 15VDC, 720A

Performance & power quality

  • Peak efficiency: 93.5% @ 380VAC (AC→DC); 92% @ 380VAC (DC→AC)
  • Power factor: 0.99 @ 380VAC (full load, grid THDu ≤2%)
  • THDi: <5% @ 380VAC (full load, grid THDu ≤2%)
  • Isolation: bidirectional high-frequency isolation; soft-switching technology

Integration & scaling

  • Communication: CAN
  • Parallel expansion: up to 4 units connected in parallel
  • Cooling: forced-air cooling with intelligent control
  • Airflow: default front inlet & rear outlet; “R type” rear inlet & front outlet

Applications & compliance

  • Typical uses: cell formation & test equipment, energy-recycling power aging equipment
  • Why it stands out: no neutral current, seamless bidirectional energy flow, modular auto-parallel operation
  • Compliance targets (per specification): excellent EMC meeting EN 55032 and other international standards; can pass UL/CE/TÜV certification (system-dependent)

Derating applies in the specified low-voltage AC range. Final certification outcomes depend on the complete system.

Download

Get in Touch with TPS
Name*
Business Email*
Company Name
Country/Region
Inquiry Type*
Application / Industry
What problem are you facing right now?
What are you trying to achieve?
Target Timeline
Budget Range
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.